INSTALLATION OF VENTING SYSTEM COMPONENTS
WARNING
Refer to the LAARS EVERHOT® IGI series Water Heater Installation and Operating Instruction
Manual for details concerning vent system termination positions/clearances, allowable vent pipe lengths, and
in what position dip switch #1 should be placed. If you do not understand how to configure your vent pipe
system and/or which position dip switch #1 should be placed in, please contact your supplier for assistance.
WARNING
All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the venting system
installation to prevent any possible leakage into the room.
Make sure all the pipe connections are firmly pressed together so that the gaskets form a tight seal.
Prior to the Installation of EVERHOT® direct vent systems:
The EVERHOT® IGI water heaters have two adjustable wall mounting support brackets fitted on
the top and bottom of the appliance. When installing a “Standard Vent Discharge Kit" to vent
directly through the wall to the back of the water heater, these brackets should be adjusted so
that the water heater is spaced its maximum distance of 2" (5.1 cm) away from the wall. Before
cutting the vent terminal to the appropriate length, ensure you have taken into account just how
far the heater has been spaced away from the wall.
NOTICE
When mounting the water heater on an outside wall, be sure the Vent/Air Intake Pipe will exit between the
wall studs. DO NOT cut through the wall studs for the Vent/Air Intake Pipe opening.
When installing the EVERHOT® IGI model series direct vent water heaters, use only EVERHOT
vent/air intake system kits and components. Installation and service must be performed by a
qualified installer, service agency or the gas supplier. Installation must meet all state and local
codes regarding installation and location of vent systems for direct vent appliances. In the
absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1,
Natural Gas and
Propane Installation Code. The maximum vent length, as stated in the EVERHOT IGI model series
Water Heater Installation and Operating Instruction Manual and these instructions, should never be
exceeded. Follow the instructions below and all instructions located in the EVERHOT IGI model
series Water Heater Installation and Operating Instruction Manual when installing a vent pipe
system. Improper installation of vent piping, or failure to follow all installation instructions
completely, can result in property damage, and/or death.
WARNING
LAARS EverHot®
Doc. 11046
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - LAARS EverHot®

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING Refer to the LAARS EVERHOT® IGI series Water Heater Installation and Operating In

Page 2 - WARNING

10 NOTICE Note: 3.5” (90 mm) is the minimum outer cap length. If needed the length outside the wall may exceed this dimension. Final installat

Page 3

11Horizontal Vent System Installation examples Figure 36

Page 4

12Installation Instructions Everhot Vertical Discharge Vent System Figure 37 Identify the vent location Determine the location where the roof dis

Page 5

13Mounting the vent system Figure 39 Vent connections must be firmly pressed together so that the gaskets form an airtightseal. Secure the system

Page 6

14Vertical Vent System Installation examples Figure 40

Page 7

15Cut Line Template

Page 8 - BWC p/n 239-44492-00

800.900.9276 • Fax 800.559.1583 (Customer Service, Service Advisors)20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 (Applicat

Page 9 - NOTICE

2 WARNING All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the venting system installation to prevent a

Page 10

3 * For clearances not specified in ANSI Z223.1 / NFP A 54 or CGA-B149, please use clearances in accordance with local installation codes and the

Page 11 - Installation examples

4 General Installation Instructions Joint connection Figure 13 Vent connections others must be firmly pressed together so that the gaskets form a

Page 12 - Figure 38

5Condensate drain Every vent system should have a condensate collector unless installed with a total vent length of less than 5 ft. (1,52 m).

Page 13 - NOTE

6 Parts & Dimensions Components needed for direct vent applications: Figure 19 Figure 20 1) horizontal discharge adapter 2) vertical di

Page 14 - Vertical Vent System

7 Figure 23 Figure 24 Figure 25 5) vent extension 6) 45º vent pipe elbow 7) 90 º vent pipe elbow 10” BWC p/n 239-44496-00

Page 15 - Cut Line Template

8 Figure 30 Figure 31 12) flat roof flashing 13) condensate trap kit BWC p/n 239-44492-00

Page 16 - (Applications Engineering)

9Installation Instructions Everhot Horizontal Discharge Vent System Identify the vent location Figure 32 Steps: - Place horizontal discharge adap