Laars Mighty Therm AP (Sizes 2000-5000) - Installation, User Manual

Browse online or download User Manual for Water boiler Laars Mighty Therm AP (Sizes 2000-5000) - Installation, . LAARS Mighty Therm AP (Sizes 2000-5000) - Installation, Operation and Maintenance Instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Installation and Operation Instructions Document 3094E
H2000000E
Installation
and Operation
Instructions for
Mighty Therm
Pool Heating Boiler
Model AP
Sizes 2000-5000
FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician,
qualified in hot water boiler installation and maintenance. Improper installation and/or operation could
create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death.
Improper installation and/or operation will void the warranty.
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a nearby phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or gas
supplier.
These instructions are to be stored in the packet provided on the boiler.
A subsidiary of BRADFORD WHITE
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - Model AP

Installation and Operation Instructions Document 3094EH2000000EInstallationand OperationInstructions forMighty ThermPool Heating BoilerModel APSizes 2

Page 2 - TABLE OF CONTENTS

Page 10LAARS Heating Systems3A-3. Hi-Limit CheckoutAfter running the boiler for a long enough periodto bring the water temperature within the range of

Page 3 - Installation

Mighty Therm Commercial Pool Heating BoilerPage 113F. Time Clock OperationDuring the initial warm-up period, the boilermust run continuously. Therefor

Page 4

Page 12LAARS Heating SystemsSECTION 4.Maintenance1. At start-up and every six (6) months thereafter,the pilot and main burner flame should beobserved

Page 5

Mighty Therm Commercial Pool Heating BoilerPage 13SECTION 5.Troubleshooting and Analysis ofService Problems1. For proper service and problem diagnosis

Page 6 - 2E. Gas Supply and Piping

Page 14LAARS Heating SystemsSECTION 6.Conversion of Model AP Pool BoilersFrom Indoor to Outdoor ModelsPlease read the following instructions withFigur

Page 7 - 2H. General Water Piping

Mighty Therm Commercial Pool Heating BoilerPage 15Figure 12. Outdoor Parts. Referenced on page 14.

Page 8 - 2K. Pressure Switch

Page 16LAARS Heating SystemsSECTION 7.Parts Description and Order NumbersI=Indoor, E=Outdoor. Quantity is 1, unless otherwise noted.Key Size Size Size

Page 9 - Operation

Mighty Therm Commercial Pool Heating BoilerPage 17Figure 13. Parts Identification.*Indoor parts only**For tiles, see Figure 15.

Page 10 - 3E. Winter Operation

Page 18LAARS Heating SystemsI=Indoor, E=Outdoor. Quantity is 1, unless otherwise noted.Key Size Size Size Size Size Size SizeNo. Description 2000 I 24

Page 11 - 3I. Pool Water Chemistry

Mighty Therm Commercial Pool Heating BoilerPage 19Figure 14. Built-in Automatic Control Valve.Rod retainer101337Spring shaftS00196SpringSpring guideS0

Page 12 - Maintenance

Page 2LAARS Heating SystemsTABLE OF CONTENTSSECTION 1.General Information1A. Introduction... 3SECTION

Page 13 - Service Problems

Figure 15. Tile Assembly.H2000000E800.900.9276 • Fax 800.559.1583 (Customer Service, Service Advisors)20 Industrial Way, Rochester, NH 03867 • 603.335

Page 14 - From Indoor to Outdoor Models

Mighty Therm Commercial Pool Heating BoilerPage 3SECTION 1.General InformationIMPORTANT WARNING:The Model AP commercial pool boilers must beused with

Page 15

Page 4LAARS Heating SystemsAll boilers must be installed on a non-combustible floor. Under no circumstances can boilersbe installed on carpeting.The N

Page 16 - SECTION 7

Mighty Therm Commercial Pool Heating BoilerPage 52B-2. Venting1. Laars boilers have built-in draft diverters fornatural draft operation and must not b

Page 17 - **For tiles, see Figure 15

Page 6LAARS Heating Systems4. Liquified petroleum is heavier than air.Therefore, the pool boiler should not be installedin pits or other locations whe

Page 18 - LAARS Heating Systems

Mighty Therm Commercial Pool Heating BoilerPage 7Arrangement of gas train components for on-offfiring are shown schematically in the Gas PipingDiagram

Page 19

Page 8LAARS Heating SystemsTherefore, the temperature difference betweenthe inlet and out pipes will be so small as to bedifficult to sense by touchin

Page 20 - Figure 15. Tile Assembly

Mighty Therm Commercial Pool Heating BoilerPage 9pool. If this condition exists, follow this procedure toadjust the switch:1. With the boiler on, the

Comments to this Manuals

No comments